Adjustable, Direct-Acting Cartridge Relief Valve
					Adjustable, Direct-Acting Cartridge Relief Valve
Order code

 


Symbol

 


Outline Dimension

Operation
The valve prevents flow from ① to ② until the set crack pressure at  ① is achieved.
The poppet then unseats allowing flow from ① to ② protecting the circuit from over pressurization.
Technical data
Operating Pressure: 27MPa
Flow: 10L/min
Temperature: -35℃ to +120℃
Cavity: 08-2
				
				
				
				
					
				